Do Epidurals Cause Autism? (No.) A Review of the Controversy and What Patients and Providers Need to Know

Caroline Thomas, MD; Jennifer M. Banayan, MD

Background

EpiduralAutism is a developmental disorder characterized by persistent deficits in communication and social interaction and is often associated with the presence of stereotypic or repetitive behaviors.1 The incidence of autism in the United States is increasing and has prompted research directed at identifying risk factors for autism.2,3

The true etiology of autism is unknown. For 40 years, research has focused on perinatal and neonatal exposures and their relation to autism, and yet no definitive answers have been identified.4 Obstetric and delivery factors in addition to neonatal exposures have been examined, and many of the results have been inconsistent.5 Despite inconsistencies in the literature, most experts agree that the mechanism underlying the etiology of autism includes a combination of environmental and genetic risk factors.5 On October 12, 2020, an article titled “Association between epidural analgesia during labor and risk of autism spectrum disorders in offspring” was published in JAMA Pediatrics.6 The article sparked debate and garnered multiple responses and critiques. This review will formally describe the existing literature on the potential for a correlation between epidurals and autism, provide a description of the controversy, and discuss important points for patients and providers to consider.

The JAMA Pediatrics Article

The authors’ objective was to assess whether lumbar epidural anesthesia (LEA) exposure was associated with an increased risk of developing autism in offspring. The study is a retrospective longitudinal cohort analysis of 147,895 singleton children born via vaginal delivery at 28–44 weeks gestational age in the Kaiser Permanente Southern California hospital system between Jan 1, 2008, and Dec 31, 2015.

Both anesthetic records and autism evaluations were readily available to researchers for review because the investigators had access to a systemwide electronic medical record system and a standardized method to evaluate children for autism at both 18 and 24 months.

In the JAMA Pediatrics study, the authors reported a 74.2% epidural usage rate, and they found that a significantly higher percentage (1.9%) of children in the LEA group received a diagnosis of autism spectrum disorder (ASD) versus 1.3% of children in the non-LEA group (HR 1.37, 95% CI 1.23–1.53). Of the children born to mothers in the LEA group, longer duration of exposure to LEA was associated with greater ASD risk (HR 1.05 per 4 hours of LEA exposure, 95% CI 1.01–1.09). In their discussion, the authors express concern regarding the safety and long-term health of offspring exposed to LEA and suggest further research is needed to identify the mechanism of the association between LEA and autism.6

The Response

Critics of the study expressed concerns over both methodology and the clinical implications of the study. On the same day the above article was published, five medical societies that represent more than 100,000 physicians including the American Society of Anesthesiologists, American College of Obstetricians and Gynecologists, Society for Obstetric Anesthesia and Perinatology, the Society for Pediatric Anesthesia, and the Society for Maternal-Fetal Medicine released a joint statement aimed to reassure pregnant women that neuraxial analgesia is safe, effective, and the “gold standard for labor pain relief.” The statement iterates that the study “does not provide credible scientific evidence that labor epidurals for pain relief cause autism” and cautions against implying causation from an observational study.7 They reinforce the safety of epidurals based on the experience of millions of women each year and questioned the biological plausibility of the study given the low levels of drug exposure to the fetus in the setting of low-dose epidural local anesthetic and opiates used in common practice. They encouraged women to continue to utilize safe ways to relieve pain for a positive childbirth experience.

Table 1: Comparison of 2020–2021 Retrospective Analyses

Table 1: Comparison of 2020–2021 Retrospective Analyses

ASD: autism spectrum disorder, LEA: labor epidural analgesia, HR: hazard ratio, CI: confidence interval

Several retrospective population-based studies from Canada and Denmark aimed at re-evaluating the association between epidurals and autism were published which contradicted the findings in the JAMA Pediatrics article (Table 1).8-10 The follow-up studies increased the number of covariates in an attempt to minimize residual confounding, and some performed multiple sensitivity analyses to evaluate for potential bias. Of the three studies, two found no association between LEA and ASD.8,10 One study from British Columbia, Canada, indicated a small, but statistically significant association between epidural analgesia and autism.11 However, multiple sensitivity analyses within the study did not show an association, and based on their findings, the authors reported that given the high likelihood of residual confounding, the results do not provide sufficient evidence for an association.

Beyond medical societies, numerous individuals published critiques, criticisms, and letters to the editor with their own concerns related to the original article. The Editor in Chief of JAMA Pediatrics published an Editor’s Note in response to the article, noting that his “personal assessment is that the association is yet to be definitively established. If a more definitive study is done, JAMA Pediatrics will publish it.”12 Many experts expressed concerns over residual and uncontrolled confounding in the original article.12-15 For example, some responses suggested that the presence or absence of ASD in the parents should have been considered in the original study considering that ASD is estimated to be 40–80% genetically determined.16 Others questioned the biological plausibility of how low-dose local anesthetic administered to the mother just a few hours before birth could lead to enough local anesthetic toxicity to permanently affect the developing brain.9,13-15 There is very sparse data regarding any causal relationship between LEA and abnormal neurologic development in both humans and animals.17–20

Another interesting revelation is that studies attempting to identify a correlation between ASD and LEA all identified substantial baseline differences between women who do and do not receive epidural analgesia. Some of these confounding differences include maternal age, race, ethnicity, education level, household income, maternal diabetes, pre-eclampsia, and gestational age.21 These differences suggest that women receiving epidural analgesia may be inherently different than those who did not. As it is difficult to account for global aspects of maternal health such as general mental state, nutrition, self-care/prenatal care, residual confounding may remain in not only the original article, but in the subsequent retrospective studies as well.21

Epidural ProcedureLEA offers a number of important benefits to women during labor. Neuraxial analgesia provides superior pain management as compared to IV analgesia or nitrous oxide.22 The presence of an epidural catheter in situ acts as a safety mechanism for women requiring urgent or emergent cesarean delivery by potentially preventing the increased risks associated with general anesthesia, improves post-partum pain scores, and allows maternal participation in bonding immediately after cesarean delivery.22,23 Consequently, one of the most serious concerns with the JAMA Pediatrics study is the inference of a causal relationship between LEA and ASD leading to significant maternal anxiety and guilt over choosing LEA for labor pain relief. This could lead to a reduction in LEA usage, which has the potential to increase rates of general anesthesia for emergent cesarean delivery, which in turn may increase neonatal exposure to maternal medications and increase maternal morbidity.15,16,22-25
The authors of the JAMA Pediatrics article suggested that their findings indicate the importance of future research to “better understand the neurodevelopmental safety of LEA to our children.”26

Although it is clearly stated in the discussion of the JAMA Pediatrics article that there is no causal relationship between LEA and autism, it is difficult to glean this point from the title and abstract of the article.6 Noncausal associations can sometimes be misinterpreted by the general public, and inaccurate representation of data in the media is common. One example of this is the assumption that vaccines cause autism, a concern that initiated from a single, subsequently retracted, study from the Lancet in 1998 that has subsequently led to widespread vaccine hesitancy, which the WHO has labelled one of the top 10 threats to global health.27,28 Great care should be taken when discussing risks and benefits of epidurals with patients to dispel inaccuracies and emphasize the safety of epidurals.

In conclusion, no subsequent publication has found conclusive evidence of an association or correlation between LEA and ASD, despite more rigorous methodology. When discussing risks and benefits with our patients, care should be taken to reinforce the safety profile of LEA. While concerns regarding the association between ASD and LEA by patients should not be dismissed, the current literature supports neither a correlation nor a causative relationship between the two, and that fact should be firmly reiterated to all our patients.

 

Caroline Thomas, MD, is an obstetric anesthesiology fellow at Northwestern University Feinberg School of Medicine.

Jennifer Banayan, MD, is an associate professor of anesthesiology at Northwestern University Feinberg School of Medicine. She is also editor of the APSF Newsletter.


The authors have no conflicts of interest.


References

  1. American Psychiatric Association. Diagnostic and statistical manual of mental disorders. Published online 2013. https://www.ncbi.nlm.nih.gov/nlmcatalog/101604226
  2. Myers SM, Voigt RG, Colligan RC, et al. Autism spectrum disorder: incidence and time trends over two decades in a population-based birth cohort. J Autism Dev Disord. 2019;49:1455-1474. doi.org/10.1007/s10803-018-3834-0
  3. Maenner MJ, Shaw KA, Baio J, et al. Prevalence of autism spectrum disorder among children aged 8 years — Autism and Developmental Disabilities Monitoring Network, 11 Sites, United States, 2016. Mmwr Surveill Summ. 2020;69:1–12.
  4. Glasson EJ, Bower C, Petterson B, et al. Perinatal factors and the development of autism: a population study. Arch Gen Psychiat. 2004;61:618–627. doi.org/10.1001/archpsyc.61.6.618
  5. Gardener H, Spiegelman D, Buka SL. Perinatal and neonatal risk factors for autism: a comprehensive meta-analysis. Pediatrics. 2011;128:344–355. doi.org/10.1542/peds.2010-1036
  6. Qiu C, Lin JC, Shi JM, et al. Association between epidural analgesia during labor and risk of autism spectrum disorders in offspring. Jama Pediatr. 2020;174:1168-1175. doi.org/10.1001/jamapediatrics.2020.3231
  7. Joint statement of the Society for Obstetric Anesthesia and Perinatology, the American Society of Anesthesiologists, the Society of Pediatric Anesthesia, the American College of Obstetricians and Gynecologists, and the Society for Maternal-Fetal Medicine. Labor epidurals do not cause autism; safe for mothers and infants, say anesthesiology, obstetrics, and pediatric medical societies. Published online October 12, 2020. https://soap.memberclicks.net/assets/docs/JAMAPeds_Epidurals_SOAP_ASA_SPA_ACOG_SMFM_Media_Response_101220%20%281%29.pdf
  8. Wall-Wieler E, Bateman BT, Hanlon-Dearman A, et al. Association of epidural labor analgesia with offspring risk of autism spectrum disorders. Jama Pediatr. 2021;175:698–705. doi.org/10.1001/jamapediatrics.2021.0376
  9. Hanley GE, Ip A, Oberlander TF. Epidural analgesia and autism spectrum disorder risk—the challenges inherent in complex observational research. Jama Pediatr. 2021;175:675–677. doi.org/10.1001/jamapediatrics.2021.0382
  10. Mikkelsen AP, Greiber IK, Scheller NM, Lidegaard Ø. Association of labor epidural analgesia with autism spectrum disorder in children. JAMA. 2021;326:1170–1177. doi.org/10.1001/jama.2021.12655
  11. Hanley GE, Bickford C, Ip A, et al. Association of epidural analgesia during labor and delivery with autism spectrum disorder in offspring. JAMA. 2021;326:1178–1185. doi.org/10.1001/jama.2021.14986
  12. Christakis DA. More on epidurals and autism. JAMA Pediatr. 2021;175:705–705. https://doi.org/10.1001/jamapediatrics.2021.0385
  13. Carrier FM, Lavoie A, Zaphiratos V. Epidural analgesia during labour and autism risk: getting lost on the causal path. Can J Anaesth. 2021;68:277–284. doi.org/10.1007/s12630-020-01880-5
  14. Glezerson BA, Trivedi V, McIsaac DI. On the stated association between labour epidural analgesia and risk of autism spectrum disorder in offspring. Can J Anaesth. 2021;68:428–429. doi.org/10.1007/s12630-020-01869-0
  15. Kern-Goldberger AR, Burris HH, Levine LD. Methodologic concerns with concluding a link between epidural and autism spectrum disorder. JAMA Pediatr. 2021;175:536–537. doi.org/10.1001/jamapediatrics.2020.6692
  16. Saito M, Nakamura K, Hirota K. Concerns for labor analgesia and autism spectrum disorders. J Anesth. 2021;35:319–320.doi.org/10.1007/s00540-020-02880-x
  17. Decocq G, Brazier M, Hary L, et al. Serum bupivacaine concentrations and transplacental transfer following repeated epidural administrations in term parturients during labour. Fundam Clin Pharm. 1997;11:365–370. doi.org/10.1111/j.1472-8206.1997.tb00850.x
  18. Sakuma S, Oka T, Okuno A, et al. Placental transfer of lidocaine and elimination from newborns following obstetrical epidural and pudendal anesthesia. Pediatr Pharmacol. (New York). 1985;5:107–115.
  19. Demeulemeester V, Hauthem HV, Cools F, Lefevere J. Transplacental lidocaine intoxication. J Neonatal Perinatal Med. 2018;(Preprint):1–3. doi.org/10.3233/npm-1791
  20. Cabrera OH, Gulvezan T, Symmes B, et al. Sex differences in neurodevelopmental abnormalities caused by early-life anaesthesia exposure: a narrative review. Brit J Anaesth. 2020;124:e81–e91. doi.org/10.1016/j.bja.2019.12.032
  21. Wong CA, Stevens H. Labor epidural analgesia and autism spectrum disorder. JAMA. 2021;326:1155–1157. doi.org/10.1001/jama.2021.15369
  22. Lim G, Facco FL, Nathan N, Waters JH, Wong CA, Eltzschig HK. A review of the impact of obstetric anesthesia on maternal and neonatal outcomes. Anesthesiology. 2018;129:192–215. doi.org/10.1097/aln.0000000000002182
  23. McQuaid E, Leffert LR, Bateman BT. The role of the anesthesiologist in preventing severe maternal morbidity and mortality. Clin Obstet Gynecol. 2018;61:372–386. doi.org/10.1097/grf.0000000000000350
  24. Palanisamy A. Maternal anesthesia and fetal neurodevelopment. Int J Obstet Anesth. 2012;21:152–162. doi.org/10.1016/j.ijoa.2012.01.005
  25. Chien LN, Lin HC, Shao YHJ, et al. Risk of autism associated with general anesthesia during cesarean delivery: a population-based birth-cohort analysis. J Autism Dev Disord. 2015;45:932–942. doi.org/10.1007/s10803-014-2247-y
  26. Qiu C, Desai V, Xiang AH. Methodologic concerns with concluding a link between epidural and autism spectrum disorder—reply. JAMA Pediatr. 2021;175:537–538. doi.org/10.1001/jamapediatrics.2020.6695
  27. Geoghegan S, O’Callaghan KP, Offit PA. Vaccine safety: myths and misinformation. Front Microbiol. 2020;11:372. dx.doi.org/10.3389%2Ffmicb.2020.00372
  28. Godlee F, Smith J, Marcovitch H. Wakefield’s article linking MMR vaccine and autism was fraudulent. Brit Med J. 2011;342:c7452. doi.org/10.1136/bmj.c7452
Continue Reading