APSF Technology Education Initiative (TEI) : Low-Flow Anesthesia
A Primer on the Environmental Rationale for the Practice of Low-Flow Anesthesia
The environmental impacts of greenhouse gases (GHG) are well known and include planetary warming causing rising sea levels and extreme weather events. Morbidity and mortality are associated with the resulting changes in vector ecology, food and water insecurity, extreme heat, increasing allergens, environmental degradation, and air pollution. Inhaled anesthetics are potent greenhouse gases (GHG) and contribute to the climate crisis.
Anesthesia and surgical care are lifesaving interventions yet highly energy and resource intensive. The US has the highest healthcare associated emissions per capita, but despite this, does not achieve the best health outcomes.
There is great variability in the environmental impact of anesthetic care depending on how that care is delivered and which anesthetics are administered. The relative greenhouse impact of anesthetic gases is compared to carbon dioxide using a measure called global warming potential over a 100-year time horizon (GWP100) to account for variable persistence in the atmosphere. Desflurane has a GWP100 of 2540, meaning it is 2540 times as potent as CO2 over a 100-year time horizon. Isoflurane’s GWP100 is 510, sevoflurane’s is 130, and nitrous oxide’s is 298. Isoflurane and nitrous oxide also deplete the ozone layer. Emissions from volatile anesthetics can be as much as 5–7% of a hospital’s total emissions.
Strategies to reduce the environmental impact of inhaled anesthetics include:
- Eliminate the use of the highest-impact gases—Desflurane and Nitrous Oxide
- Decommission centrally piped nitrous oxide due to the significant leakage in these systems
- Lower fresh gas flows (FGF) while using volatile anesthetics to minimize the environmental impact. To learn more follow the link to the course on practicing low-flow anesthesia at apsf.org/TEI/LFA.
Incorporating these strategies into your practice can dramatically reduce emissions while preserving a safe and effective patient experience. Plus, they won’t be able to blame us for global warming either!
Elizabeth E Hansen, MD, PhD, Is a pediatric anesthesiologist at Seattle Children’s Hospital and an assistant professor at the Department of Anesthesiology and Pain Medicine, University of Washington.
References
- Health care climate footprint report. Health Care Without Harm. Published January 14, 2020. https://noharm-uscanada.org/content/global/health-care-climate-footprint-report. Accessed March 16, 2022.
- Eckelman MJ, Huang K, Lagasse R, et al. Health care pollution and public health damage in the United States: An update. Health Aff. 2020;39:2071–2079. PMID: 33284703
- White SM, Shelton CL, Gelb AW, et al. Principles of environmentally-sustainable anaesthesia: a global consensus statement from the World Federation of Societies of Anaesthesiologists. Anaesthesia. Published online November 1, 2021. doi:10.1111/anae.15598. PMID: 34724710
- Gordon D. Sustainability in the Operating Room: Reducing Our Impact on the Planet. Anesthesiol Clin. 2020;38:679–692. PMID: 32792191
- Patient Safety and Low-Flow Anesthesia. Anesthesia Patient Safety Foundation. Published June 1, 2022. https://dev2.apsf.org/article/patient-safety-and-low-flow-anesthesia/. Accessed July 7, 2022.
- Powell BJ, Waltz TJ, Chinman MJ, et al. A refined compilation of implementation strategies: results from the Expert Recommendations for Implementing Change (ERIC) project. Implement Sci. 2015;10:21. PMID: 25889199
- Sherman J. Yale Gassing Greener App. https://jscalc.io/calc/H7gGXIL4tmDJHOxh. Accessed June 4, 2022.
- Kennedy RR, Hendrickx JF, Feldman JM. There are no dragons: Low-flow anaesthesia with sevoflurane is safe. Anaesth Intensive Care. 2019;47:223–225. PMID: 31124374
- Sherman J, Le C, Lamers V, Eckelman M. Life cycle greenhouse gas emissions of anesthetic drugs. Anesth Analg. 2012;114:1086–1090 PMID: 22492186.
- Vetter TR, Morrice D. Statistical Process Control: No Hits, No Runs, No Errors? Anesth Analg. 2019;128:374–382. PMID: 30531221
- Sherman JD, Chesebro BB. Inhaled anaesthesia and analgesia contribute to climate change. BMJ. 2022;377:o1301. PMID: 35675944